For institutional clients
Gas turbines from 20 to 300 MW+
We work only with institutional clients and with the plants and title holders themselves: AI infrastructure developers, IPPs and energy companies on one side, the owners of the units on the other.
Send a requirement Selling a turbine
- 20 to 300 MW+
- Aeroderivative and frame, per unit
- New, used, surplus
- Title verified on every existing unit
- 50 and 60 Hz
- Conversions scoped where needed
Plant owners and title holders
Sell a gas turbine or a whole plant
Whether it is running, idle, mothballed or being decommissioned, we place turbines and whole plants directly with the AI infrastructure developers and energy companies we work with, and prepare an indicative market valuation.
Model, MW, frequency, hours run and location are enough to start. We sign an NDA before you send serials or title documents. You need to hold title or act for the owner.
Tell us what you are holding or email powergen@mccordinvestments.com
AI infrastructure developers, IPPs and energy companies
Buying a turbine
Tell us what you need and when. We tell you what exists against it and work it directly with the plants and title holders.
Send the model or class and MW per unit, 50 or 60 Hz and fuel, the site, the date on site and the condition you will accept.
How we work
This is a market of scarcity, and we give an honest read of it: what exists against your date and who holds it. A handful of trusted partners work with us, every inquiry comes to us directly, and we never take ownership of the equipment.
The electrical package
Our clients also get their transformers, switchgear and E-houses through us, quoted alongside the generation, on lead times well inside the market average. See the lead times
Why we never publish a list
Published listings get passed between brokers, which slows every real sale. We bring units to qualified buyers privately, one requirement at a time.
- 1
A qualified requirement
A buyer sends the unit, the size, the site and the date.
- 2
We match it
Against the units plants and title holders bring to us directly.
- 3
We verify it
Identity, title and records are confirmed before anything moves.
- 4
Placed with a qualified buyer
An institutional client with an active project.
Models we work
Units, and the gas generators and parts that travel with them. If you hold one of these, tell us.
Ansaldo
- AE64.3A Frame
- AE94.3A Frame
GE Vernova
- 7E Frame
- 9E Frame
- LM2500 Aeroderivative
- LM6000 Aeroderivative
- LMS100 Aeroderivative
- TM2500 Aeroderivative
Mitsubishi Power
- FT8 SwiftPac Aeroderivative
- H-25 Frame
- M501F Frame
- M501G Frame
- M501J Frame
- M701F Frame
Siemens Energy
- SGT-800 Industrial
- SGT-A65 (Trent 60) Aeroderivative
- SGT5-4000F Frame
- SGT6-5000F Frame
- V64.3 Frame
Aeroderivative and frame
Aeroderivative
20 to 100+ MW
- Built from aircraft engine designs
- Compact, and quick to start
- Peaking plants, data centres and mobile power
Frame
30 to 300+ MW
- Heavier industrial machines
- Peaking to base load
- Often in combined cycle
Per unit, for the units we work.
50 Hz and 60 Hz
60 Hz
North America
50 Hz
Europe, Africa, Australia and most of Asia
South America is split. Large frame units are built for one frequency or the other. Some aeroderivatives and geared frames can be set up for either. Where a unit needs converting, we scope it with specialist engineers: generator, gearbox and controls.
New, used and surplus
-
New
From the manufacturer's production slots. Large frame turbines can mean a long wait.
-
Used
From operating, idle or mothballed plants.
-
Unused surplus
Built and never installed.
For a used unit, hours since overhaul, inspection records and storage drive much of what it is worth.
Buying a used generator? Run it as good as new
A used generator is only as good as its windings. The used generator packages we source for our clients come with the option of a rewind in place, in collaboration with Preformed Windings and its accredited service centre network. The old stator winding is replaced with a new one on a current insulation system: new-machine reliability, for less cost and lead time than buying new.
- 1
Assess
Condition assessment, electrical and mechanical inspection, measurements and 3D scans.
- 2
Manufacture
Preformed Windings designs and manufactures the new stator winding.
- 3
Strip and rewind
An accredited service centre removes the old winding, inspects the stator and installs the new set in place.
- 4
Test and restart
Start-up, loop, excitation and protection checks, then back in service.
- One point of responsibility. Warranties, design, manufacture and installation under one contract.
- Obsolete OEM design. Reverse engineered from 3D scans, with engineered replacements.
- Modern insulation. Resin-rich insulation that runs cooler, with updated generator curves as an option.
- Qualified by OEMs. Preformed Windings is a qualified supplier to multiple OEMs.
For hydro generators, turbogenerators and large HV motors. Logo, photos and credentials: Preformed Windings.
For plant owners and institutional clients
Indicative market valuations
What a unit or a whole plant is worth today, from our read of the market.
Common questions
What size of gas turbine do you work with?
Mostly 20 to 300 MW and above per unit, aeroderivative and frame. Aeroderivatives run from about 20 MW to over 100 MW, and frame units from about 30 MW to over 300 MW, depending on model and vintage.
Do you look at new and used units?
Yes, both, against your date. A new unit can mean a long wait for a large frame turbine; used and surplus units are already built.
What should a used turbine's generator file include?
Before a used turbine package is sold or commissioned, the buyer's engineers will ask for the generator's test history: insulation resistance and polarization index (IEEE 43), partial discharge results and trend, tan delta, and the date and scope of the last rewind. Nameplate photos and the latest inspection report help. If the results point to a rewind, plan for it early, because new stator coils usually set the schedule. We can arrange new stator coils and a rewind where needed.